Publications

Bink H, Lai Y, Saudari SR, Helfer B, Viventi J, Van der Spiegel J, Litt B, Kagan C. Flexible organic electronics for use in neural sensing. Conf Proc IEEE Eng Med Biol Soc 2011; 2011 5400-5403.

Choi SO, Kim YC, Lee JW, Park JH, Prausnitz MR, Allen MG. Intracellular protein delivery and gene transfection by electroporation using a microneedle electrode array. Small Apr 10 2012; 8 (7): 1081-1091.

Choi Y, McClain MA, LaPlaca MC, Frazier AB, Allen MG. Three dimensional MEMS microfluidic perfusion system for thick brain slice cultures. Biomed Microdevices Feb 2007; 9 (1): 7-13.

Christ KV, Turner KT. Methods to Measure the Strength of Cell Adhesion to Substrates. Journal of Adhesion Science and Technology 2010; 24 (13-14): 2027-2058.

Christ KV, Turner KT. Design of hydrodynamically confined microfluidics: controlling flow envelope and pressure. Lab Chip Apr 21 2011; 11 (8): 1491-1501.

Christ KV, Williamson KB, Masters KS, Turner KT. Measurement of single-cell adhesion strength using a microfluidic assay. Biomed Microdevices Jun 2010; 12 (3): 443-455.

Colace TV, Diamond SL. Direct observation of von Willebrand factor elongation and fiber formation on collagen during acute whole blood exposure to pathological flow. Arterioscler Thromb Vasc Biol Jan 2013; 33 (1): 105-113.

Colace TV, Tormoen GW, McCarty OJ, Diamond SL. Microfluidics and coagulation biology. Annu Rev Biomed Eng 2013; 15 283-303.

Flamm MH, Colace TV, Chatterjee MS, Jing H, Zhou S, Jaeger D, Brass LF, Sinno T, Diamond SL. Multiscale prediction of patient-specific platelet function under flow. Blood Jul 5 2012; 120 (1): 190-198.

Huh D, Leslie DC, Matthews BD, Fraser JP, Jurek S, Hamilton GA, Thorneloe KS, McAlexander MA, Ingber DE. A human disease model of drug toxicity-induced pulmonary edema in a lung-on-a-chip microdevice. Sci Transl Med Nov 7 2012; 4 (159): 159ra147.

Huh D, Torisawa YS, Hamilton GA, Kim HJ, Ingber DE. Microengineered physiological biomimicry: Organs-on-Chips. Lab Chip 2012; 12 (12): 2156-2164.

Issadore D, Franke T, Brown KA, Westervelt RM. A microfluidic microprocessor: controlling biomimetic containers and cells using hybrid integrated circuit/microfluidic chips. Lab Chip Nov 7 2010; 10 (21): 2937-2943.

Issadore D, Min C, Liong M, Chung J, Weissleder R, Lee H. Miniature magnetic resonance system for point-of-care diagnostics. Lab Chip Jul 7 2011; 11 (13): 2282-2287.

Issadore D, Shao H, Chung J, Newton A, Pittet M, Weissleder R, Lee H. Self-assembled magnetic filter for highly efficient immunomagnetic separation. Lab Chip Jan 7 2011; 11 (1): 147-151.

Koser AE, Pan L, Keim NC, Arratia PE. Measuring material relaxation and creep recovery in a microfluidic device. Lab Chip May 21 2013; 13 (10): 1850-1853.

Li R, Fries S, Li X, Grosser T, Diamond SL. Microfluidic assay of platelet deposition on collagen by perfusion of whole blood from healthy individuals taking aspirin. Clin Chem Aug 2013; 59 (8): 1195-1204.

Liu C, Mauk MG, Hart R, Bonizzoni M, Yan G, Bau HH. A low-cost microfluidic chip for rapid genotyping of malaria-transmitting mosquitoes. PLoS One 2012; 7 (8): e42222.

Liu C, Mauk MG, Hart R, Qiu X, Bau HH. A self-heating cartridge for molecular diagnostics. Lab Chip Aug 21 2012; 11 (16): 2686-2692.

Maloney SF, Brass LF, Diamond SL. P2Y12 or P2Y1 inhibitors reduce platelet deposition in a microfluidic model of thrombosis while apyrase lacks efficacy under flow conditions. Integr Biol (Camb) Apr 2010; 2 (4): 183-192.

Muthard RW, Diamond SL. Blood clots are rapidly assembled hemodynamic sensors: flow arrest triggers intraluminal thrombus contraction. Arterioscler Thromb Vasc Biol Dec 2012; 32 (12): 2938-2945.

Muthard RW, Diamond SL. Side view thrombosis microfluidic device with controllable wall shear rate and transthrombus pressure gradient. Lab Chip May 21 2013; 13 (10): 1883-1891.

Neeves KB, Diamond SL. A membrane-based microfluidic device for controlling the flux of platelet agonists into flowing blood. Lab Chip May 2008; 8 (5): 701-709.

Neeves KB, Illing DA, Diamond SL. Thrombin flux and wall shear rate regulate fibrin fiber deposition state during polymerization under flow. Biophys J Apr 7 2010; 98 (7): 1344-1352.

Neeves KB, Maloney SF, Fong KP, Schmaier AA, Kahn ML, Brass LF, Diamond SL. Microfluidic focal thrombosis model for measuring murine platelet deposition and stability: PAR4 signaling enhances shear-resistance of platelet aggregates. J Thromb Haemost Dec 2008; 6 (12): 2193-2201.

Norman JJ, Choi SO, Tong NT, Aiyar AR, Patel SR, Prausnitz MR, Allen MG. Hollow microneedles for intradermal injection fabricated by sacrificial micromolding and selective electrodeposition. Biomed Microdevices Apr 2013; 15 (2): 203-210.

Puig-de-Morales-Marinkovic M, Turner KT, Butler JP, Fredberg JJ, Suresh S. Viscoelasticity of the human red blood cell. Am J Physiol Cell Physiol Aug 2007; 293 (2): C597-605.

Qiu X, Chen D, Liu C, Mauk MG, Kientz T, Bau HH. A portable, integrated analyzer for microfluidic – based molecular analysis. Biomed Microdevices Oct 2011; 13 (5): 809-817.

Ricart BG, Yang MT, Hunter CA, Chen CS, Hammer DA. Measuring traction forces of motile dendritic cells on micropost arrays. Biophys J Dec 7 2011; 101 (11): 2620-2628.

Shen XN, Sznitman J, Krajacic P, Lamitina T, Arratia PE. Undulatory locomotion of Caenorhabditis elegans on wet surfaces. Biophys J Jun 20 2012; 102 (12): 2772-2781.

Viventi J, Kim DH, Vigeland L, Frechette ES, Blanco JA, Kim YS, Avrin AE, Tiruvadi VR, Hwang SW, Vanleer AC, Wulsin DF, Davis K, Gelber CE, Palmer L, Van der Spiegel J, Wu J, Xiao J, Huang Y, Contreras D, Rogers JA, Litt B. Flexible, foldable, actively multiplexed, high-density electrode array for mapping brain activity in vivo. Nat Neurosci Dec 2011; 14 (12): 1599-1605.

Welsh JD, Colace TV, Muthard RW, Stalker TJ, Brass LF, Diamond SL. Platelet-targeting sensor reveals thrombin gradients within blood clots forming in microfluidic assays and in mouse. J Thromb Haemost Sep 15 2012;

Comments are closed