Microfluidic focal thrombosis model for measuring murine platelet deposition and stability

Collagen patterning and blood flow device

Collagen patterning and blood flow device

Neeves KB, Maloney SF, Fong KP, Schmaier AA, Kahn ML, Brass LF, Diamond SL. Microfluidic focal thrombosis model for measuring murine platelet deposition and stability: PAR4 signaling enhances shear-resistance of platelet aggregates. J Thromb Haemost Dec 2008; 6 (12): 2193-2201.

Objective: To measure murine platelet deposition and stability in response to focal zones of prothrombotic stimuli using 100 μL of whole blood and controlled flow exposure.

Methods: Microfluidic methods were used for patterning acid-soluble collagen in 100 μm × 100 μm patches and creating flow channels with a volume of 150 nL. Within 1 min of collection into PPACK and fluorescent anti-mouse CD41 mAb, whole blood from normal mice or from mice deficient in the integrin α2 subunit was perfused for 5 min over the patterned collagen. Platelet accumulation was measured at venous and arterial wall shear rates. After 5 min, thrombus stability was measured with a ‘shear step-up’ to 8000 s−1.

Schematic of collagen patterning and blood flow experiments.

Schematic of collagen patterning and blood flow experiments.

Results: Wild-type murine platelets adhered and aggregated on collagen in a biphasic shear-dependent manner with increased deposition from 100 to 400 s−1, but decreased deposition at 1000 s−1. Adhesion to patterned collagen was severely diminished for platelets lacking a functional α2β1 integrin. Those integrin α2-deficient platelets that did adhere were removed from the surface when challenged to shear step-up. PAR4 agonist (AYPGKF) treatment of the thrombus at 5 min enhanced aggregate stability during the shear step-up.

Conclusions: PAR4 signaling enhances aggregate stability by mechanisms independent of other thrombin-dependent pathways such as fibrin formation.

References

Neeves KB, Maloney SF, Fong KP, Schmaier AA, Kahn ML, Brass LF, Diamond SL. Microfluidic focal thrombosis model for measuring murine platelet deposition and stability: PAR4 signaling enhances shear-resistance of platelet aggregates. J Thromb Haemost Dec 2008; 6 (12): 2193-2201.

Bookmark the permalink.

Comments are closed